welcome To Shijiazhuang Dekun Technology Co., Ltd. Official website!
Language: 中文版 ∷  英文版

Data acquisition module

  • DK61DND OLED single phase DC multi-function power meter guide rail installation

DK61DND OLED single phase DC multi-function power meter guide rail installation

  • Voltage compatible AC/DC multi-range input, can distribute voltage transformer to expand range; Current compatible AC/DC multi-range input, can distribute current transformer to expand range; Digital filtering, effective filtering interference, eliminating non-critical word hopping; Can realize two relay alarm; 2 transmission and output; Communication function; True effective value measurement voltage Electric power can be measured by current and power. Guide rail installation.

  • Online orders

Detailed parameters


Model: DK61DND (DC)


Measurement accuracy: + 0.5% (+ 0.3%).


Voltage range: DC500V, DC100V


Current range: DC5A, DC100MV, DC5V


Working power: AC 90~250V (47~63HZ)


Working environment: 0 ~ + 50 C; less than 85%RH


Relay contact capacity: AC220V/5A


Relay contact life: 105 times


Variable output accuracy: 16 bits + 0.2%


Communication: photoelectric isolation RS-485 communication interface


Product features


True RMS algorithm for AC measurement


The measurement of voltage, current, power and electric energy for AC and DC.


It can be widely used in the measurement field of photovoltaic, wind power and new energy vehicles.


Digital liquid crystal display


High precision measurement


Optional MODBUS communication


It can realize 2 ways of relay alarm, and 2 way output.


Selection size


Outline size: 75mm*45mm*112mm


Installation mode: 35mm guide rail installation