DK2100 series

  • DK2104 Temperature controller, level controller, pressure controller, flow controller, four-loop controller

DK2104 Temperature controller, level controller, pressure controller, flow controller, four-loop controller

  • Dk2104 four channel universal signal input type. It can be used in conjunction with various sensors and transmitters. It can detect, alarm and control industrial process parameters such as multi-channel temperature, pressure, liquid level, flow rate, weight, current and voltage, and transmit output, data acquisition and communication.

    With the latest international electronic technology, high-speed signal processor and microprocessor as the core, digital is more intelligent.

    Equipped with photoelectric isolation RS-485 communication interface, using ModBus RTU communication protocol. The circuit design uses three terminal isolation of input, power and output.


  • Online orders

Product features

4 channel independent input

Support for 24 industrial signals

Support 2 channel transmit output

Support 2 channel relay alarm output

Support for Modbus Communication

input Signals

Thermocouple signalThermal resistance signalVoltage signalCurrent signal
KCu500~20mV4~20mA
SPT1000~100mV0~20mA
R0~80Ω0~1V
T0~400Ω1~5V
E
0~5V
J
-20~+20mV
B
-100~+100mV
N
-5V~+5V
WRe3-WRe25



WRe5-WRe26


Output signals

Voltage signal0-5V1-5v0-10v
Current signal0-10ma0-20ma4-20ma

communication

Photoelectric isolation RS-485 communication interface

alarm
2 channel relay output

Other detailed parameters

Number of input channels4 independent channels, different input types.
Input signal range24 common industrial standard signals.
Range-1999~9999
Basic error0.2%FS + 1 words.
Resolution1/11998
Measure AD20 bits, 25SPS
Output DA16 bits, 200KSPS
Input impedance

when the voltage is greater than or equal to 500K, the current is less than 300 ohms,

the thermal resistance is less than 0.25mA, and the thermocouple is more than 500K

Output impedance (with load capacity)

voltage (> 250K) and current (< 300_). (Current has special requirements, 

can do 650 euro, explain when ordering

relayAC120V/1A, DC30V/1A
Display modedigital tube
Sampling period0.32S/0.64S
Communication modeRS485 interface, two wire system.
Communication protocolMODBUS RTU
Supply voltageAC220V
Isolation voltage2000V AC 1 minutes.
Working conditionstemperature: -20 ~ +50 C, humidity: 10% ~ 90%RH
Storage conditionstemperature: -40 ~ +80 C, humidity: 10% ~ 90%RH
Opening size92*92mm